(816) 608-7745Get pricingBook a demo

Scanner comparison

Artec Spider II vs Artec Micro II

Both capture small, detailed parts in color without targets. The Spider II is a handheld scanner you move around the part; the Micro II is a desktop scanner that moves the part for you and measures far more tightly.

Key takeaways

  • Stated accuracy: 0.05 mm for the Spider II and 5 microns (0.005 mm) for the Micro II.
  • The Spider II is handheld and takes objects of about 5 to 50 cm; the Micro II takes objects up to 200 × 200 × 150 mm and 2 kg.
  • The Micro II scans automatically after one click, which keeps results consistent between operators.
  • Both scan without targets and record color texture.
  • Both run in Artec Studio, so Spider II and Micro II data can sit in one project.

Which should you choose: Artec Spider II or Artec Micro II?

Choose the Artec Spider II when your parts range from coin size up to something like an engine component, and you want to hold the scanner and capture fine detail anywhere: it is rated at 0.05 mm accuracy and resolution and is used on parts that cannot be moved or marked. Choose the Artec Micro II when every part fits within 200 × 200 × 150 mm and you need the tightest numbers and repeatable, one-click results: 5-micron accuracy certified to ISO 12836 and 2-micron repeatability, with the stage moving the part along a computed path. The Spider II is the more flexible tool; the Micro II is the more precise and consistent one.

Who the Artec Spider II suits

  • Reverse engineering of small and medium parts with sharp edges, thin ribs and fine lines.
  • Parts that cannot be moved or marked: finished surfaces, evidence, museum pieces.
  • Mixed part sizes from coin-sized up to engine components.
  • Teams that already scan with a Leo or Eva and want a fine-detail partner in Artec Studio.

Read the full Artec Spider II page

Who the Artec Micro II suits

  • Inspection of precision parts that fit within 200 × 200 × 150 mm.
  • Dental, jewelry and medical components that need 5-micron accuracy.
  • Repeat measurement where results must not depend on the operator.
  • Labs that want one-click automated scanning on the bench.

Read the full Artec Micro II page

How do the Spider II and Micro II specs compare?

The table lines up the published specifications of the Spider II and the Micro II, read from artec3d.com and never retyped. Where a scanner comes in several models, a cell shows the range across them or names each model. 'Not published' means the maker does not state that figure. Compare single-point accuracy with volumetric accuracy at your own part length, then check targets, color and wireless use against the way your team works. The verdict above explains which differences matter for which jobs.

Artec Spider II vs Artec Micro II: specifications
SpecificationArtec Spider IIArtec Micro II
TechnologyBlue-light structured lightStructured light (RGB LED), automated desktop
Product classHandheld high-resolution blue-light 3D scannerAutomated desktop 3D scanner
Accuracy0.05 mm5 microns (0.005 mm)
RepeatabilityNot published2 microns
Resolution0.05 mm40 microns
Measurement speedUp to 8,000,000 points/sUp to 1,000,000 points/s
Field of view128 × 104 mm / 171 × 152 mmØ 20 × 15 cm
Recommended part size50–500 mm200 × 200 × 150 mm, 2 kg
Positioning targetsNot neededNot needed
Color textureYesYes
ConnectionCompatible with Thunderbolt 4 hostsUSB 3.0
Weight0.95 kg12 kg
Accuracy testVDI/VDE 2634 Part 3, ISO/IEC 17025-accredited labISO 12836

Specs checked:

How do a handheld and a desktop scanner differ?

The Spider II is a handheld blue-light scanner: you move it around the object from 0.19 to 0.3 m away, and it tracks on geometry and texture at up to 30 frames per second. The Micro II is an automated desktop unit: you place the part on its motorized stage, click once, and the software moves the part along a computed path while four 13 MP cameras capture it. The handheld approach reaches parts in place and larger parts; the desktop approach removes the operator's hand from the result, which is why its accuracy and repeatability figures are so much tighter. Both record color and need no targets.

Person in a white coat scanning a small lattice part on a turntable with the Artec Spider II, laptop open beside it
Thin struts and tight curves like these are the detail people choose a 0.05 mm scanner for.

Which is more accurate?

The Micro II, by an order of magnitude. Artec states 5-micron (0.005 mm) point accuracy for the Micro II, certified to ISO 12836, with 2-micron repeatability and 40-micron resolution. The Spider II is rated at 0.05 mm accuracy and 0.05 mm resolution, with 0.05 mm + 0.3 mm/m over distance, and each unit ships with a certificate from Artec's ISO/IEC 17025-accredited lab. For inspecting connectors, valves, dental items and precision components, the Micro II's figures are the ones that matter. For capturing fine features such as engravings, edges and thin ribs to rebuild in CAD, the Spider II's 0.05 mm is usually ample.

Which is easier to use?

The Micro II asks the least of the operator: place, click, wait. Artec Studio plans the path and the number of frames, so two people scanning the same part get the same result, which suits production inspection. The Spider II takes a little technique, since you hold it close and move it steadily, but Artec Studio's Autopilot and real-time fusion make it quick to learn. The Spider II weighs 0.95 kg and connects by Thunderbolt; the Micro II is a 12 kg desktop unit on USB 3.0 that stays on the bench.

Which parts suit each scanner?

The Micro II takes objects up to 200 × 200 × 150 mm and 2 kg: engine valves, electrical connectors, watch parts, dental items, small castings and small medical components. An optional third axis reaches undercuts. The Spider II covers small and medium objects, roughly 5 to 50 cm, and Artec cites parts from a coin up to a car engine. It also suits objects that cannot go on a stage, such as parts in an assembly, evidence or museum pieces. If your parts are all small and tolerances tight, the Micro II fits; if sizes vary or parts stay in place, the Spider II fits.

What else do buyers ask about the Artec Spider II and the Artec Micro II?

Can the Spider II scan parts as small as the Micro II does?

It can capture small parts, from about coin size, and its 0.05 mm resolution picks up inscriptions and sharp edges. The Micro II resolves finer detail and measures far more accurately on small parts, at 5 microns with 40-micron resolution, and its automated stage gives consistent coverage. For tiny precision parts, the Micro II is the stronger tool.

Do the Spider II and Micro II need targets?

Neither does. The Spider II tracks its position on the object's geometry and color texture, and the Micro II's four cameras and motorized stage handle positioning, so small parts stay clean and fine detail is not covered by markers. That also suits medical, forensic and finished parts that must not be touched.

What is the largest part the Micro II can scan?

Artec recommends objects up to 200 × 200 × 150 mm and up to 2 kg, held on the motorized stage. Anything larger belongs on a handheld scanner, and the Spider II is the usual next step. Both run in Artec Studio, so you can scan small components on the Micro II and their larger housings with the Spider II in one project.

Which is better for quality inspection?

For small precision parts, the Micro II: its 5-micron accuracy, 2-micron repeatability and automatic scanning make it suited to production inspection, with results compared to CAD in Artec Studio or Geomagic Control X. The Spider II also inspects, at 0.05 mm, and fits parts that are too big for the Micro II's stage or cannot be moved.

See the Artec Spider II and the Artec Micro II on your own work

Tell us the job that is hardest to measure today. We scan it where it is and show you the result, so you compare on your own work, not on a spec sheet. On-site demos are available in most areas; ask when you request.

Call (816) 608-7745