Key takeaways

  • Accuracy is how close a measurement is to the true value; resolution is how finely the scanner samples the surface.
  • Volumetric accuracy adds a length term, so the error budget grows with part size: 0.020 mm + 0.040 mm/m works out to 0.100 mm over a 2 m part.
  • Measurement resolution and mesh resolution are different specs, and a finer mesh does not make a scanner more accurate.
  • Read the test method beside every figure: ISO 10360, VDI/VDE 2634 part 3 and ISO/IEC 17025-accredited labs appear on the spec sheets of the scanners we supply.
  • A photogrammetry frame or scale bars shrink the length term on large parts, for example to 0.020 mm + 0.015 mm/m on a HandySCAN BLACK Elite with a MaxSHOT NEXT Elite.

Two scanners can both claim hundredths of a millimeter and still give very different results on your part. The reason is usually in the small print: one figure is accuracy on a small reference sphere, another is resolution, and a third is volumetric accuracy over a measuring volume. Mix them up and you can choose a scanner that looks right on paper but cannot hold your tolerance across a long part.

This guide untangles the terms, shows how the makers test them and works through examples with real figures from scanners we supply, such as the HandySCAN BLACK Elite and the Artec Point II.

In this article

What is the difference between accuracy and resolution?

Accuracy tells you how close a measured point or dimension is to the true value. Resolution tells you how finely the scanner samples the surface: the spacing between measured points, or the smallest feature it can record. A scanner can record fine detail in slightly the wrong place, which is high resolution with poor accuracy, or place a sparse set of points very truly, which is the reverse. For inspection, accuracy decides whether you can trust a deviation. For reverse engineering and small features, resolution decides whether an edge, a fillet or engraved text survives in the mesh.

A third word, precision or repeatability, describes how closely repeated measurements agree with each other. A scanner can be repeatable and still consistently off, which is why calibration matters. Artec quotes both figures for the Artec Micro II desktop scanner: 3D point accuracy of 5 microns and repeatability of 2 microns, with ISO 12836 listed as its accuracy standard.

Measurement resolution versus mesh resolution

Spec sheets often list two resolutions. Measurement resolution is the fineness of the raw points the sensor records. Mesh resolution is the spacing of the triangles in the finished model, which the software sets and you can often adjust. On the HandySCAN BLACK Elite the measurement resolution is 0.025 mm and the mesh resolution 0.100 mm. On the HandySCAN MAX EVO they are 0.04 mm and 0.4 mm, because a scanner built for parts up to 15 m trades fine detail for coverage.

Accuracy and resolution on four scanners we supply
ScannerAccuracyResolutionWhat that resolution suits
Creaform HandySCAN BLACK Elite0.025 mm0.025 mm measurement, 0.100 mm meshMachined detail on parts from 0.05 to 4 m
Creaform HandySCAN MAX EVO Elite0.075 mm0.04 mm measurement, 0.4 mm meshLarge surfaces and structures rather than fine features
Artec Spider II0.05 mm0.05 mmSmall, intricate parts and fine surface texture
Artec LeoUp to 0.1 mmUp to 0.2 mm in HD modeMedium to large objects captured quickly in color

How does volumetric accuracy work?

Single-point accuracy is measured on a small artefact close to the scanner. On a real part the scanner moves, and small positioning errors add up with distance. Volumetric accuracy captures that by adding a length term to a fixed term. A figure such as 0.020 mm + 0.040 mm/m means a fixed 0.020 mm plus 0.040 mm for every meter of part length, so a 2 m part works out to 0.100 mm. Because the length term dominates on big parts, compare volumetric figures at your own part length whenever parts are longer than a few hundred millimeters.

Technician scanning a long welded steel frame outdoors with a wireless handheld 3D scanner
On a long frame like this one, the length term of the volumetric accuracy matters more than the single-point figure.

Work it out for your own part:

  1. Find the volumetric accuracy on the spec sheet, for example 0.020 mm + 0.040 mm/m on the HandySCAN BLACK Elite.
  2. Take your longest part dimension in meters.
  3. Multiply the length term by that length, then add the fixed term.
  4. Compare the result with the tightest tolerance on that part, using your plant's own ratio between tolerance and measurement uncertainty.

Using Creaform's formulas, a 10 m part works out to 0.175 mm on the HandySCAN MAX EVO Elite (0.075 mm + 0.010 mm/m) and to 0.350 mm on the MAX EVO (0.150 mm + 0.020 mm/m). On long parts, the Elite's smaller length term matters more than its single-point figure.

Tracked systems state the same idea differently. The MetraSCAN 3D BLACK+ Elite is rated at 0.064 mm over a 9.1 m³ volume and 0.075 mm over 16.6 m³, because the C-Track's measuring volume, not the distance the scanner travels, sets the error budget.

How do makers test these figures?

Credible figures come with a named test. Creaform runs acceptance tests in ISO/IEC 17025-accredited calibration labs: the HandySCAN EVO Elite is tested based on ISO 10360, the family of standards for coordinate measuring systems, while the EVO, EVO Plus, BLACK Elite and MAX Series are tested based on VDI/VDE 2634 part 3, a guideline for optical systems that measure from several views. Artec tests the Neo and Spider II to VDI/VDE 2634 Part 3 in its accredited lab, and lists ISO 17025 accreditation based on VDI/VDE 2634 and JJF 1951 for the Point II.

Standards move on. DIN Media now lists VDI/VDE 2634 part 3 as withdrawn and names DIN EN ISO 10360-13, the part of the ISO 10360 series for optical 3D coordinate measuring systems, as its replacement. Spec sheets still cite the guideline, and its tests remain a meaningful, repeatable check. If a spec sheet you are reading quotes ISO 10360-13, it refers to that newer part.

Shrinking the length term on large parts

When parts get long, the biggest accuracy gain often comes from a better reference frame rather than a different scanner. A photogrammetry camera or a set of calibrated scale bars fixes accurate reference points across the whole part first, and the scanner then works inside that frame, so most of its own length term no longer applies.

Photogrammetry camera on an extension pole beside a box of coded targets
A photogrammetry camera and coded targets fix reference points across a long part before scanning, which shrinks the length term.

The frame keeps the scanner's fixed term and replaces its length term, so a HandySCAN BLACK Elite goes from 0.020 mm + 0.040 mm/m on its own to 0.020 mm + 0.015 mm/m with a MaxSHOT NEXT Elite, and the EVO Plus and Elite reach the same figure with the Accu+ Kit scale bars. Our guide to photogrammetry for large-part scanning tabulates the published figures for each pairing and explains how the frame is built, and the large-parts buyer's guide lists the scanners we recommend for multi-meter work.

Questions to settle before you request a quote

  • Is the accuracy figure single-point or volumetric, and over what length or volume?
  • Which standard or guideline was the acceptance test based on, and was the lab accredited?
  • Which resolution is quoted: measurement or mesh?
  • Does the best figure depend on targets, scale bars or a photogrammetry frame?
  • What does the volumetric figure work out to at your longest part?

Have those answers ready for a demo, along with the part that worries you most. Our specialists scan it, compare the result with your CAD model and show the deviation map, so you judge the numbers on your own geometry. On-site demos are available in most areas; ask when you request one. The on-site demo page explains what to prepare, and the quality inspection guide lists the scanners we recommend for tolerance work.

Frequently asked questions

What does 0.020 mm + 0.040 mm/m mean on a 3D scanner?

It is a volumetric accuracy figure with two parts. The first, 0.020 mm, is a fixed term that applies to any measurement. The second, 0.040 mm per meter, grows with the length of the part. Add them for your part: on the HandySCAN BLACK Elite, whose figure this is, a 2 m part works out to 0.100 mm. Compare that result, not the fixed term, with your tolerance.

Is a higher-resolution 3D scanner always better?

No. Higher resolution captures finer detail, but it also makes larger files and slower processing, and it does not improve accuracy on its own. A scanner for large structures, such as the HandySCAN MAX EVO with its 0.4 mm mesh resolution, deliberately trades detail for coverage. Choose the resolution your smallest important feature needs, then check accuracy separately.

What is the difference between accuracy and precision?

Accuracy is how close a measurement is to the true value. Precision, often called repeatability, is how closely repeated measurements of the same feature agree with each other. A scanner can be very repeatable yet consistently offset, which calibration corrects. Artec states both for the Micro II: 5 microns of 3D point accuracy and 2 microns of repeatability.

Why do tracked scanners quote accuracy per volume?

On a tracked system such as the MetraSCAN 3D or HandyPROBE, an optical tracker measures the scanner's or probe's position, so the error depends on where the device sits within the tracker's measuring volume rather than on how far the scanner has travelled. Creaform therefore states figures such as 0.064 mm over 9.1 m³ for the Elite models, with larger volumes rated separately.