Industry guides
How to reverse engineer a pump impeller from a 3D scan
Reverse engineering a pump impeller from a 3D scan: capture blades and passages, choose a worn copy or a rebuilt design, then cast, machine or print it.

Key takeaways
- An impeller is a hard scan: narrow passages between curved blades, shrouds that hide the vanes, and worn edges that no longer show the original design.
- Capture the hub, shrouds and blades with overlap, scanning each passage from the eye and from the outlet, and use targets only where accuracy must hold.
- Decide early whether you need a copy of the worn impeller or a rebuild of the intended design, because they lead to different CAD models.
- Rebuild the hub and shrouds as revolved features around the shaft axis, and fit surfaces to one blade before patterning it.
- Check the CAD model against the scan, and against a second impeller if you have one, before you cast, machine or print the replacement.
A pump in a refinery, a mine or a water plant can outlive its maker's support. When the impeller wears out and the supplier has no drawing, or no longer exists, the old impeller is the only record of the design. Our energy industry page covers scanning across power, oil and gas; this guide covers one job the general scan-to-CAD guides skip: turning a worn impeller into a replacement.
Impellers bring their own problems: passages you cannot see into, blades that twist, and edges worn away by years of flow. Here is how to scan one, what to model, and which tools help. For the wider scanner choice, see our best 3D scanners for reverse engineering.
In this article
Why is an impeller hard to scan?
Because most of what matters is hidden. On a closed impeller the vanes sit between two shrouds, so each passage is a narrow, curved tunnel that a scanner can see into only from the eye and the outlet. Blades twist from hub to tip, and their leading and trailing edges are thin. Worn impellers add erosion, pitting and cavitation damage, so the surface you scan is not the surface that was designed. Finish varies too, from dull castings to bright machined bores. A good scan plan deals with each of these before the first pass.

Artec built its Neo for geometry like this: it names impeller passages, pockets and channels among the deep features the Neo captures as they are, where targets cannot be applied. In hybrid mode it uses targets only where a tolerance must hold and scans target-free everywhere else, in one dataset.
Scanning an impeller, step by step
- Clean the impeller and remove scale and deposits from the blades, without grinding away worn surfaces you want to record.
- Mount it on a fixture or turntable so you can reach the eye, the outlet and both shrouds without handling it between passes.
- Scan the outer surfaces first: hub, shrouds, eye and bore, with targets on the fixture or on non-critical areas where accuracy over the whole impeller must hold.
- Scan each passage from the eye and from the outlet, angling the scanner into the gaps so the two views overlap in the middle.
- Check coverage in the software and rescan any blade faces or edges with holes before you take the impeller off the fixture.
- Merge the scans into one watertight mesh and keep the raw data, so the modeler can go back to it.
If part of a passage stays out of view from both ends, note where. The modeler then knows which surfaces were measured and which were filled in from the visible sections of the same blade.
Should you copy the worn impeller or rebuild the design?
Decide before modeling. A worn copy follows the scan closely, erosion and all, which is rarely what you want, because the replacement would start life already worn. A design-intent rebuild restores the original form: true blade surfaces, sharp edges where they were sharp, consistent blade thickness and clean shrouds. It takes more judgment, and where wear is heavy the original shape has to be inferred from the least-worn areas or from a second impeller. Either way, leave blade angles, passage areas and diameters to your pump engineer, because those govern how the pump behaves.
How is an impeller rebuilt in CAD?
Start with the axis. Fit a cylinder to the bore or a plane to the hub face, and align the model so the shaft axis is a CAD axis. Take a section through that axis and revolve it to build the hub and shrouds. For the blades, cut sections at several radii on the least-worn blade, fit curves to them, and loft surfaces for its pressure and suction sides. Close the blade, pattern it around the axis by the blade count, and trim it to the hub and shroud. Finish with root fillets and a check against the scan.

| Feature | Taken from the scan | Modeled as |
|---|---|---|
| Bore and keyway | Cylinder and plane fits | Exact features at standard sizes, checked against the shaft |
| Hub and shrouds | A section through the shaft axis | A revolved profile |
| Blades | Sections at several radii on the least-worn blade | Lofted surfaces, closed and then patterned |
| Eye and outlet edges | Least-worn areas and any second impeller | Restored edges, with your engineer's approval |
| Blade roots | Local scan detail | Fillets matched to the casting |
Creaform Scan-to-CAD fits cylinders and planes, cuts cross-sections and, in the Pro version, revolves and extrudes solids; Artec Studio fits primitives and exports STEP, IGES or X_T to SOLIDWORKS or Geomagic Design X. Our scan-to-CAD guide covers the general mesh-to-solid rebuild, which we do not repeat here.
Which scanners suit impellers?
Pick by size and by how deep the passages are. For small and medium impellers, the Artec Neo and Spider II work 0.19 to 0.3 m from the surface and capture thin edges in detail; the Neo adds targets where a tolerance must hold, rated at 0.025 mm + 0.035 mm/m. For larger impellers and pump casings, the HandySCAN EVO's blue laser handles bright machined and dull cast metal alike, and the wireless Artec Leo covers big components in the field, away from a laptop. Plan to scan the casing and wear rings too, because the new impeller has to fit them.
Our HandySCAN EVO vs Artec Leo comparison sets the laser and structured-light options side by side for larger pump work, and the Artec Neo page lists its full specifications.
Scanners for impeller work:
From CAD model to replacement impeller
Once the model is checked, the route to a new impeller depends on size, material and how many you need. Large impellers are usually cast, so the CAD model becomes a pattern or a printed sand mold, with machining stock added on the bore, the hub faces and the wear-ring fits. Smaller impellers may be machined from solid on a five-axis machine or 3D printed in metal or polymer. Whichever route you take, scan the first replacement and compare it with the CAD model and the old impeller before it goes into service.
Trying it on your own impeller
Bring the impeller that worries you most. When we visit, our specialists scan it on site, show the coverage inside the passages and walk through the alignment and the first revolved and lofted features in the software. Our guide to what a 3D scanner can scan covers cast, machined and worn metal surfaces.
Frequently asked questions
Can you 3D scan inside a closed impeller?
Partly. A scanner sees into the passages from the eye and the outlet, and a compact scanner angled into the gaps captures most of each blade. The middle of a long, narrow passage may stay hidden. Overlap the views from both ends, note any unseen areas, and model those surfaces from the visible sections of the same blade.
Do I need the original drawings to reverse engineer an impeller?
No. The scan provides the geometry, and a second impeller of the same design helps separate wear from the original form. Any surviving information still helps: the pump's data plate, the blade count, the impeller diameter on a data sheet, or the material. Share what you have with whoever models and makes the replacement.
Will a scanned replacement impeller perform like the original?
We make no performance claim for a rebuilt impeller, and nobody should without testing it. A careful rebuild restores the measured geometry; whether the pump then performs as it did is for your pump engineer and a test to confirm. Changes to blade angles, passage areas or diameter belong to that engineer.
What accuracy does impeller reverse engineering need?
Enough for the fits and a faithful blade shape. Bore, keyway and wear-ring diameters are machined to tolerance after casting, so the scan mainly needs to locate them correctly, while blade and passage surfaces need complete coverage more than extreme accuracy. Scanners such as the Artec Neo, at 0.025 mm with targets, or the HandySCAN EVO, at 0.025 mm, are well inside what this work asks.
Can the same scan session cover the pump casing?
Yes, and it should. Scan the volute or diffuser and the wear rings while the pump is open, because the new impeller has to fit the casing as it is now, not as it was drawn. Comparing the casing scan with the impeller model catches clearance problems before the replacement is made.
Products in this article
ArtecNeo
Wireless hybrid handheld metrology scanner
0.025 mmBest accuracy
A wireless handheld scanner that uses targets only where a tolerance must hold and scans target-free everywhere else.
- Part size
- 50–500 mm
- Targets
- Optional
ArtecLeo
Wireless handheld 3D scanner with onboard processing
0.1 mmBest accuracy
A fully wireless scanner with its own screen, processor and battery for medium to large objects.
- Part size
- 0.2–2 m
- Targets
- Not needed
CreaformHandySCAN EVO
Handheld metrology-grade blue-laser 3D scanner
0.020 mmBest accuracy
Creaform's flagship handheld laser scanner, with a touchscreen on the scanner, AR guidance on the EVO Plus and Elite, and a wireless option with the Mobility Kit.
- Part size
- 0.05–4 m
- Targets
- Required
CreaformScan-to-CAD
Reverse-engineering software module for 3D scan data
Reverse-engineering module that turns scans into CAD-ready meshes, entities and, in the Pro version, solid models.
- Part of
- Creaform Metrology Suite
- IGES/STEP CAD file import and export
- Included